Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77.258
Filtrar
1.
Ying Yong Sheng Tai Xue Bao ; 35(3): 858-866, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38646774

RESUMEN

Insect visual electrophysiological techniques are important to study the electrical characteristics of photoreceptor cells and visual neurons in insects, including electroretinography (ERG) and microelectrode intracellular recording (MIR). ERG records the changes of voltage or electric current in the retina of insects in response to different light stimuli, which occurs outside the cell. MIR records the changes in individual photoreceptor cells or visual neurons of an insect exposed to different lights, which occurs inside the cell. Insect visual electrophysiological techniques can explore the mechanism of electrophysiological response of insects' vision to light and reveal their sensitive light spectra and photoreceptor types. This review introduced the basic structure and the principle of ERG and MIR, and summarized their applications in insect researches in the past 20 years, which would provide references for elucidating the mechanism of light perception in insects and the use of insect phototropism to control pests.


Asunto(s)
Electrorretinografía , Insectos , Células Fotorreceptoras de Invertebrados , Animales , Insectos/fisiología , Electrorretinografía/métodos , Células Fotorreceptoras de Invertebrados/fisiología , Visión Ocular/fisiología , Microelectrodos , Fenómenos Electrofisiológicos , Electrofisiología/métodos
3.
J Pharmacol Toxicol Methods ; 126: 107496, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38432527

RESUMEN

An adverse effect of drug candidates, seizure is a serious issue in drug development. Improving evaluation systems for seizure liability is crucial for selecting good candidates. Firstly, in vitro electrophysiological measurement by a multielectrode array system in rat hippocampal brain slices was employed to confirm an increase in electrically evoked population spike (PS) area, the occurrence of multiple population spikes (MPSs), and thereby the seizure liability of five positive control chemicals: picrotoxin, 4-aminopyridine, pentylenetetrazole, penicillin G, and chlorpromazine. Aspirin, a negative control, did not affect PS area or generate MPSs. Furthermore, baclofen, an anticonvulsant drug, decreased PS area and inhibited the increase in PS area or occurrence of MPSs induced by picrotoxin. A comparative study of seizure liability among carbapenem antibiotics revealed that tienam > carbenin > omegacin and finibax. Despite leading to a strong decrease in PS area, physostigmine, cisplatin, and paroxetine still produced MPSs. Therefore, the increase in PS area or the occurrence of the MPS are considered significant evaluation parameters for seizure liability. In contrast, the in vitro electrophysiological measurement could not detect the seizure liability of diphenhydramine or fluvoxamine. A follow-up study of in vivo mouse behavioral change induced by intracerebroventricular administration of these drugs clearly detected convulsions. The in vitro electrophysiological study using hippocampal brain slices combined with in vivo behavior observation study of drug candidates administered by intracerebroventricular injection can implement to assess the seizure liability of even small amounts, especially in the early stages of drug development.


Asunto(s)
Técnicas de Observación Conductual , Convulsiones , Ratas , Ratones , Animales , Picrotoxina/efectos adversos , Estudios de Seguimiento , Convulsiones/inducido químicamente , Electrofisiología , Hipocampo , Encéfalo
4.
J Neurosci ; 44(11)2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38479812

RESUMEN

The axon is a neuronal structure capable of processing, encoding, and transmitting information. This assessment contrasts with a limiting, but deeply rooted, perspective where the axon functions solely as a transmission cable of somatodendritic activity, sending signals in the form of stereotypical action potentials. This perspective arose, at least partially, because of the technical difficulties in probing axons: their extreme length-to-diameter ratio and intricate growth paths preclude the study of their dynamics through traditional techniques. Recent findings are challenging this view and revealing a much larger repertoire of axonal computations. Axons display complex signaling processes and structure-function relationships, which can be modulated via diverse activity-dependent mechanisms. Additionally, axons can exhibit patterns of activity that are dramatically different from those of their corresponding soma. Not surprisingly, many of these recent discoveries have been driven by novel technology developments, which allow for in vitro axon electrophysiology with unprecedented spatiotemporal resolution and signal-to-noise ratio. In this review, we outline the state-of-the-art in vitro toolset for axonal electrophysiology and summarize the recent discoveries in axon function it has enabled. We also review the increasing repertoire of microtechnologies for controlling axon guidance which, in combination with the available cutting-edge electrophysiology and imaging approaches, have the potential for more controlled and high-throughput in vitro studies. We anticipate that a larger adoption of these new technologies by the neuroscience community will drive a new era of experimental opportunities in the study of axon physiology and consequently, neuronal function.


Asunto(s)
Axones , Neuronas , Axones/fisiología , Potenciales de Acción/fisiología , Fenómenos Electrofisiológicos , Electrofisiología
5.
PLoS One ; 19(3): e0298320, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38483943

RESUMEN

BACKGROUND: Deep Brain Stimulation (DBS), applying chronic electrical stimulation of subcortical structures, is a clinical intervention applied in major neurologic disorders. In order to achieve a good clinical effect, accurate electrode placement is necessary. The primary localisation is typically based on presurgical MRI imaging, often followed by intra-operative electrophysiology recording to increase the accuracy and to compensate for brain shift, especially in cases where the surgical target is small, and there is low contrast: e.g., in Parkinson's disease (PD) and in its common target, the subthalamic nucleus (STN). METHODS: We propose a novel, fully automatic method for intra-operative surgical navigation. First, the surgical target is segmented in presurgical MRI images using a statistical shape-intensity model. Next, automated alignment with intra-operatively recorded microelectrode recordings is performed using a probabilistic model of STN electrophysiology. We apply the method to a dataset of 120 PD patients with clinical T2 1.5T images, of which 48 also had available microelectrode recordings (MER). RESULTS: The proposed segmentation method achieved STN segmentation accuracy around dice = 0.60 compared to manual segmentation. This is comparable to the state-of-the-art on low-resolution clinical MRI data. When combined with electrophysiology-based alignment, we achieved an accuracy of 0.85 for correctly including recording sites of STN-labelled MERs in the final STN volume. CONCLUSION: The proposed method combines image-based segmentation of the subthalamic nucleus with microelectrode recordings to estimate their mutual location during the surgery in a fully automated process. Apart from its potential use in clinical targeting, the method can be used to map electrophysiological properties to specific parts of the basal ganglia structures and their vicinity.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/terapia , Enfermedad de Parkinson/cirugía , Estimulación Encefálica Profunda/métodos , Imagen por Resonancia Magnética , Microelectrodos , Electrofisiología
6.
STAR Protoc ; 5(1): 102909, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38427565

RESUMEN

Here, we present a protocol for the fabrication of transparent implantable electrode arrays for integrating optogenetics and electrophysiology. We describe steps for fabricating microelectrodes using the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate). We then detail procedures for analyzing performance of the electrodes and recording light-evoked neural activities from the transgenic mouse. This protocol utilizes photolithography rather than conventional electrodeposition. For complete details on the use and execution of this protocol, please refer to Cho et al. (2022).1.


Asunto(s)
Optogenética , Roedores , Ratones , Animales , Microelectrodos , Electrodos Implantados , Ratones Transgénicos , Electrofisiología/métodos
7.
Nanoscale ; 16(13): 6402-6428, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38488215

RESUMEN

The peripheral nervous and muscular system, a cornerstone of human physiology, plays a pivotal role in ensuring the seamless functioning of the human body. This intricate network, comprising nerves and muscles extending throughout the body, is essential for motor control, sensory feedback, and the regulation of autonomic bodily functions. The qualified implantable peripheral interface can accurately monitor the biopotential of the target tissue and conduct treatment with stimulation, enhancing the human-machine interaction and new achievements in disease cure. Implantable electrodes have revolutionized the field of neuromuscular interfaces, offering precise bidirectional communication between the neuromuscular system and external devices. They enable natural control for individuals with limb loss, bridging the gap between mind and machine and aiding neuromuscular rehabilitation. In research and medical diagnostics, implantable electrodes provide invaluable tools for studying neuromuscular function and the development of therapies. However, traditional rigid electrodes face challenges due to the dynamic nature of the peripheral neuromuscular system. Flexible and stretchable devices show immense promise in accommodating dynamic alterations, offering adaptability, and accurate monitoring of electrophysiological signals. This review delves into the challenges associated with the peripheral interface, primarily focusing on monitoring and stimulation. It then provides a summary of common materials and structural design optimizations, discusses technologies for enhancing interface adhesion and surface functionalization, and explores encapsulation methods for implanted devices. Recent advancements in energy supply and the applications of implantable, flexible, and stretchable devices are also comprehensively reviewed, with due consideration given to ethical concerns and signal analysis. The promising directions are finally presented to provide enlightenment for high-performance sensor-tissue interfaces in the future, which will promote profound progress in clinical and human-machine interaction research. Flexible and stretchable devices are at the forefront of healthcare, with the potential to transform the treatment of neuromuscular disorders and enhance human augmentation, blurring the lines between natural and artificial limbs. They represent a promising avenue for the future, with exciting applications in healthcare, science, and technology, promising to bring us closer to the seamless integration of human and machine in the realm of neuromuscular interfaces.


Asunto(s)
Miembros Artificiales , Dispositivos Electrónicos Vestibles , Humanos , Electrodos Implantados , Electrofisiología
8.
Sci Rep ; 14(1): 6031, 2024 03 12.
Artículo en Inglés | MEDLINE | ID: mdl-38472404

RESUMEN

The dysfunction of ion channels is a causative factor in a variety of neurological diseases, thereby defining the implicated channels as key drug targets. The detection of functional changes in multiple specific ionic currents currently presents a challenge, particularly when the neurological causes are either a priori unknown, or are unexpected. Traditional patch clamp electrophysiology is a powerful tool in this regard but is low throughput. Here, we introduce a single-shot method for detecting alterations amongst a range of ion channel types from subtle changes in membrane voltage in response to a short chaotically driven current clamp protocol. We used data assimilation to estimate the parameters of individual ion channels and from these we reconstructed ionic currents which exhibit significantly lower error than the parameter estimates. Such reconstructed currents thereby become sensitive predictors of functional alterations in biological ion channels. The technique correctly predicted which ionic current was altered, and by approximately how much, following pharmacological blockade of BK, SK, A-type K+ and HCN channels in hippocampal CA1 neurons. We anticipate this assay technique could aid in the detection of functional changes in specific ionic currents during drug screening, as well as in research targeting ion channel dysfunction.


Asunto(s)
Canales Iónicos , Neuronas , Electrofisiología , Canales Iónicos/metabolismo , Neuronas/metabolismo , Membrana Celular/metabolismo , Transporte Iónico
9.
Int J Occup Med Environ Health ; 37(1): 84-97, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38375631

RESUMEN

OBJECTIVES: Emotions and stress affect voice production. There are only a few reports in the literature on how changes in the autonomic nervous system affect voice production. The aim of this study was to examine emotions and measure stress reactions during a voice examination procedure, particularly changes in the muscles surrounding the larynx. MATERIAL AND METHODS: The study material included 50 healthy volunteers (26 voice workers - opera singers, 24 control subjects), all without vocal complaints. All subjects had good voice quality in a perceptual assessment. The research procedure consisted of 4 parts: an ear, nose, and throat (ENT)­phoniatric examination, surface electromyography, recording physiological indicators (heart rate and skin resistance) using a wearable wristband, and a psychological profile based on questionnaires. RESULTS: The results of the study demonstrated that there was a relationship between positive and negative emotions and stress reactions related to the voice examination procedure, as well as to the tone of the vocal tract muscles. There were significant correlations between measures describing the intensity of experienced emotions and vocal tract muscle maximum amplitude of the cricothyroid (CT) and sternocleidomastoid (SCM) muscles during phonation and non-phonation tasks. Subjects experiencing eustress (favorable stress response) had increased amplitude of submandibular and CT at rest and phonation. Subjects with high levels of negative emotions, revealed positive correlations with SCMmax during the glissando. The perception of positive and negative emotions caused different responses not only in the vocal tract but also in the vegetative system. Correlations were found between emotions and physiological parameters, most markedly in heart rate variability. A higher incidence of extreme emotions was observed in the professional group. CONCLUSIONS: The activity of the vocal tract muscles depends on the type and intensity of the emotions and stress reactions. The perception of positive and negative emotions causes different responses in the vegetative system and the vocal tract. Int J Occup Med Environ Health. 2024;37(1):84-97.


Asunto(s)
Canto , Humanos , Fonación/fisiología , Calidad de la Voz/fisiología , Electromiografía , Electrofisiología
10.
Elife ; 122024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38345841

RESUMEN

CLC-2 is a voltage-gated chloride channel that contributes to electrical excitability and ion homeostasis in many different tissues. Among the nine mammalian CLC homologs, CLC-2 is uniquely activated by hyperpolarization, rather than depolarization, of the plasma membrane. The molecular basis for the divergence in polarity of voltage gating among closely related homologs has been a long-standing mystery, in part because few CLC channel structures are available. Here, we report cryoEM structures of human CLC-2 at 2.46 - 2.76 Å, in the presence and absence of the selective inhibitor AK-42. AK-42 binds within the extracellular entryway of the Cl--permeation pathway, occupying a pocket previously proposed through computational docking studies. In the apo structure, we observed two distinct conformations involving rotation of one of the cytoplasmic C-terminal domains (CTDs). In the absence of CTD rotation, an intracellular N-terminal 15-residue hairpin peptide nestles against the TM domain to physically occlude the Cl--permeation pathway. This peptide is highly conserved among species variants of CLC-2 but is not present in other CLC homologs. Previous studies suggested that the N-terminal domain of CLC-2 influences channel properties via a "ball-and-chain" gating mechanism, but conflicting data cast doubt on such a mechanism, and thus the structure of the N-terminal domain and its interaction with the channel has been uncertain. Through electrophysiological studies of an N-terminal deletion mutant lacking the 15-residue hairpin peptide, we support a model in which the N-terminal hairpin of CLC-2 stabilizes a closed state of the channel by blocking the cytoplasmic Cl--permeation pathway.


Asunto(s)
Canales de Cloruro CLC-2 , Animales , Humanos , Fenómenos Biofísicos , Canales de Cloruro CLC-2/química , Electrofisiología , Mamíferos/metabolismo , Péptidos/metabolismo , Microscopía por Crioelectrón
12.
Int J Cardiol ; 401: 131817, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38307422

RESUMEN

BACKGROUND: High-altitude exposure changes the electrical conduction of the heart. However, reports on electrocardiogram (ECG) characteristics and potent prophylactic agents during high-altitude acclimatization and de-acclimatization are inadequate. This study aimed to investigate the effects of ubiquinol on electrophysiology after high-altitude hypoxia and reoxygenation. METHODS: The study was a prospective, randomized, double-blind, placebo-controlled trial. Forty-one participants were randomly divided into two groups receiving ubiquinol 200 mg daily or placebo orally 14 days before flying to high altitude (3900 m) until the end of the study. Cardiopulmonary exercise testing was performed at baseline (300 m), on the third day after reaching high altitude, and on the seventh day after returning to baseline. RESULTS: Acute high-altitude exposure prolonged resting ventricular repolarization, represented by increased corrected QT interval (455.9 ± 23.4 vs. 427.1 ± 19.1 ms, P < 0.001) and corrected Tpeak-Tend interval (155.5 ± 27.4 vs. 125.3 ± 21.1 ms, P < 0.001), which recovered after returning to low altitude. Ubiquinol supplementation shortened the hypoxia-induced extended Tpeak-Tend interval (-7.7 ms, [95% confidence interval (CI), -13.8 to -1.6], P = 0.014), Tpeak-Tend /QT interval (-0.014 [95% CI, -0.027 to -0.002], P = 0.028), and reserved maximal heart rate (11.9 bpm [95% CI, 3.2 to 20.6], P = 0.013) during exercise at high altitude. Furthermore, the decreased resting amplitude of the ST-segment in the V3 lead was correlated with decreased peak oxygen pulse (R = 0.713, P < 0.001) and maximum oxygen consumption (R = 0.595, P < 0.001). CONCLUSIONS: Our results illustrated the electrophysiology changes during high-altitude acclimatization and de-acclimatization. Similarly, ubiquinol supplementation shortened the prolonged Tpeak-Tend interval and reserved maximal heart rate during exercise at high altitude. REGISTRATION: URL: www.chictr.org.cn; Unique identifier: ChiCTR2200059900.


Asunto(s)
Altitud , Capacidad Cardiovascular , Ubiquinona/análogos & derivados , Humanos , Estudios Prospectivos , Hipoxia , Aclimatación , Electrofisiología
13.
CNS Neurosci Ther ; 30(2): e14571, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38421092

RESUMEN

BACKGROUND: In α-synucleinopathies, the dysfunction of the autonomic nervous system which typically manifests as orthostatic hypotension (OH) often leads to severe consequences and poses therapeutic challenges. This study aims to discover the brain-cardiac electrophysiological changes in OH patients with α-synucleinopathies using the rapid quantitative electroencephalography (qEEG) coupled with heart rate variability (HRV) technique to identify rapid, noninvasive biomarkers for early warning and diagnosis, as well as shed new light on complementary treatment approaches such as brain stimulation targets. METHODS: In this study, 26 subjects of α-synucleinopathies with OH (α-OH group), 21 subjects of α-synucleinopathies without OH (α-NOH group), and 34 healthy controls (control group) were included from September 2021 to August 2023 (NCT05527067). The heart rate-blood pressure variations in supine and standing positions were monitored, and synchronization parameters of seated resting-state HRV coupled with qEEG were collected. Time-domain and frequency-domain of HRV measures as well as peak frequency and power of the brainwaves were extracted. Differences between these three groups were compared, and correlations between brain-heart parameters were analyzed. RESULTS: The research results showed that the time-domain parameters such as MxDMn, pNN50, RMSSD, and SDSD of seated resting-state HRV exhibited a significant decrease only in the α-OH group compared to the healthy control group (p < 0.05), while there was no significant difference between the α-NOH group and the healthy control group. Several time-domain and frequency-domain parameters of seated resting-state HRV were found to be correlated with the blood pressure changes within the first 5 min of transitioning from supine to standing position (p < 0.05). Differences were observed in the power of beta1 waves (F4 and Fp2) and beta2 waves (Fp2 and F4) in the seated resting-state qEEG between the α-OH and α-NOH groups (p < 0.05). The peak frequency of theta waves in the Cz region also showed a difference (p < 0.05). The power of beta2 waves in the Fp2 and F4 brain regions correlated with frequency-domain parameters of HRV (p < 0.05). Additionally, abnormal electrical activity in the alpha, theta, and beta1 waves was associated with changes in heart rate and blood pressure within the first 5 min of transitioning from supine to standing position (p < 0.05). CONCLUSION: Rapid resting-state HRV with certain time-domain parameters below normal levels may serve as a predictive indicator for the occurrence of orthostatic hypotension (OH) in patients with α-synucleinopathies. Additionally, the deterioration of HRV parameters correlates with synchronous abnormal qEEG patterns, which can provide insights into the brain stimulation target areas for OH in α-synucleinopathy patients.


Asunto(s)
Hipotensión Ortostática , Sinucleinopatías , Humanos , Hipotensión Ortostática/diagnóstico , Hipotensión Ortostática/terapia , Frecuencia Cardíaca/fisiología , Encéfalo/diagnóstico por imagen , Presión Sanguínea/fisiología , Electroencefalografía , Electrofisiología
14.
Circulation ; 149(10): e937-e952, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-38314551

RESUMEN

Disorders of the cardiac rhythm may occur in both the fetus and neonate. Because of the immature myocardium, the hemodynamic consequences of either bradyarrhythmias or tachyarrhythmias may be far more significant than in mature physiological states. Treatment options are limited in the fetus and neonate because of limited vascular access, patient size, and the significant risk/benefit ratio of any intervention. In addition, exposure of the fetus or neonate to either persistent arrhythmias or antiarrhythmic medications may have yet-to-be-determined long-term developmental consequences. This scientific statement discusses the mechanism of arrhythmias, pharmacological treatment options, and distinct aspects of pharmacokinetics for the fetus and neonate. From the available current data, subjects of apparent consistency/consensus are presented, as well as future directions for research in terms of aspects of care for which evidence has not been established.


Asunto(s)
American Heart Association , Arritmias Cardíacas , Recién Nacido , Estados Unidos , Niño , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/tratamiento farmacológico , Taquicardia , Feto , Electrofisiología
15.
Nanoscale Horiz ; 9(4): 544-554, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38323517

RESUMEN

Current methodology used to investigate how shifts in brain states associated with regional cerebral blood volume (CBV) change in deep brain areas, are limited by either the spatiotemporal resolution of the CBV techniques, and/or compatibility with electrophysiological recordings; particularly in relation to spontaneous brain activity and the study of individual events. Additionally, infraslow brain signals (<0.1 Hz), including spreading depolarisations, DC-shifts and infraslow oscillations (ISO), are poorly captured by traditional AC-coupled electrographic recordings; yet these very slow brain signals can profoundly change CBV. To gain an improved understanding of how infraslow brain signals couple to CBV we present a new method for concurrent CBV with wide bandwidth electrophysiological mapping using simultaneous functional ultrasound imaging (fUS) and graphene-based field effect transistor (gFET) DC-coupled electrophysiological acquisitions. To validate the feasibility of this methodology visually-evoked neurovascular coupling (NVC) responses were examined. gFET recordings are not affected by concurrent fUS imaging, and epidural placement of gFET arrays within the imaging window did not deteriorate fUS signal quality. To examine directly the impact of infra-slow potential shifts on CBV, cortical spreading depolarisations (CSDs) were induced. A biphasic pattern of decreased, followed by increased CBV, propagating throughout the ipsilateral cortex, and a delayed decrease in deeper subcortical brain regions was observed. In a model of acute seizures, CBV oscillations were observed prior to seizure initiation. Individual seizures occurred on the rising phase of both infraslow brain signal and CBV oscillations. When seizures co-occurred with CSDs, CBV responses were larger in amplitude, with delayed CBV decreases in subcortical structures. Overall, our data demonstrate that gFETs are highly compatible with fUS and allow concurrent examination of wide bandwidth electrophysiology and CBV. This graphene-enabled technological advance has the potential to improve our understanding of how infraslow brain signals relate to CBV changes in control and pathological brain states.


Asunto(s)
Grafito , Humanos , Encéfalo/diagnóstico por imagen , Convulsiones , Electrofisiología , Circulación Cerebrovascular/fisiología , Ultrasonografía
17.
Neurosci Lett ; 823: 137665, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38301912

RESUMEN

Good aerobic and metabolic fitness associates with better cognitive performance and brain health. Conversely, poor metabolic health predisposes to neurodegenerative diseases. Our previous findings indicate that rats selectively bred for Low Capacity for Running (LCR) show less synaptic plasticity and more inflammation in the hippocampus and perform worse in tasks requiring flexible cognition than rats bred for High Capacity for Running (HCR). Here we aimed to determine whether hippocampal electrophysiological activity related to learning and memory would be impaired in LCR compared to HCR rats. We also studied whether an exercise intervention could even out the possible differences. We conducted in vivo recordings from the dorsal hippocampus under terminal urethane anesthesia in middle-aged sedentary males and female rats, and in females allowed to access running wheels for 6 weeks. Our results indicate stronger long-term potentiation (LTP) in the CA3-CA1 synapse in HCR than LCR rats, and in female than male rats. Compared to LCR rats, HCR rats had more dentate spikes and more gamma epochs, the occurrence of which also correlated positively with the magnitude of LTP. Voluntary running reduced the differences between female LCR and HCR rats. In conclusion, low innate fitness links to reduced hippocampal function and plasticity which can seems to improve with voluntary aerobic exercise even in middle age.


Asunto(s)
Potenciación a Largo Plazo , Condicionamiento Físico Animal , Ratas , Masculino , Femenino , Animales , Hipocampo , Electrofisiología , Condicionamiento Físico Animal/fisiología
18.
Sci Adv ; 10(8): eadj4399, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38381836

RESUMEN

Identifying different sleep stages in humans and other mammals has traditionally relied on electroencephalograms. Such an approach is not feasible in certain animals such as invertebrates, although these animals could also be sleeping in stages. Here, we perform long-term multichannel local field potential recordings in the brains of behaving flies undergoing spontaneous sleep bouts. We acquired consistent spatial recordings of local field potentials across multiple flies, allowing us to compare brain activity across awake and sleep periods. Using machine learning, we uncover distinct temporal stages of sleep and explore the associated spatial and spectral features across the fly brain. Further, we analyze the electrophysiological correlates of microbehaviors associated with certain sleep stages. We confirm the existence of a distinct sleep stage associated with rhythmic proboscis extensions and show that spectral features of this sleep-related behavior differ significantly from those associated with the same behavior during wakefulness, indicating a dissociation between behavior and the brain states wherein these behaviors reside.


Asunto(s)
Fenómenos Fisiológicos del Sistema Nervioso , Sueño , Animales , Humanos , Sueño/fisiología , Fases del Sueño/fisiología , Drosophila/fisiología , Electrofisiología , Mamíferos
19.
J. eletrocardiol ; 84: 1-8, fev.2024. graf
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1532550

RESUMEN

BACKGROUND: Accurate estimation of accessory pathway (AP) localization in patients with ventricular pre-excitation or Wolff-Parkinson-White (WPW) syndrome remains a diagnostic challenge. Existing algorithms have contributed significantly to this area, but alternative algorithms can offer additional perspectives and approaches to AP localization. OBJECTIVE: This study introduces and evaluates the diagnostic accuracy of the EPM algorithm in AP localization, comparing it with established algorithms Arruda and EASY. METHODS: A retrospective analysis was conducted on 138 patients from Hospital São Paulo who underwent catheter ablation. Three blinded examiners assessed the EPM algorithm's diagnostic accuracy against the Arruda and EASY algorithms. The gold standard for comparison was the radioscopic position of the AP where radiofrequency ablation led to pre-excitation disappearance on the ECG. RESULTS: EPM showed a diagnostic accuracy of 51.45%, closely aligning with Arruda (53.29%) and EASY (44.69%). Adjacency accuracy for EPM was 70.67%, with Arruda at 66.18% and EASY at 72.22%. Sensitivity for EPM in distinguishing left vs. right APs was 95.73%, with a specificity of 74.33%. For identifying septal vs. lateral right APs, EPM sensitivity was 82.79% with a specificity of 46.15%. These measures were comparable to those of Arruda and EASY. Inter-observer variability was excellent for EPM, with Kappa statistics over 0.9. CONCLUSION: The EPM algorithm emerges as a reliable tool for AP localization, offering a systematic approach beneficial for therapeutic decision-making in electrophysiology. Its comparable diagnostic accuracy and excellent inter-observer variability underscore its potential clinical applicability. Future research may further validate its efficacy in a broader clinical setting.


Asunto(s)
Síndrome de Wolff-Parkinson-White , Electrofisiología , Algoritmos , Electrocardiografía , Fascículo Atrioventricular Accesorio
20.
J Neurosci Methods ; 404: 110079, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38340901

RESUMEN

BACKGROUND: Electrophysiological recording with glass electrodes is one of the best techniques to measure membrane potential dynamics and ionic currents of voltage-gated channels in neurons. However, artifactual variability of the biophysical state variables that determine recording quality can be caused by insufficient affinity between the electrode and cell membrane during the recording. NEW METHOD: We introduce a phospholipid membrane coating on glass electrodes to improve intracellular electrophysiology recording quality. Membrane-coated electrodes were prepared with a tip-dip protocol for perforated-patch, sharp-electrode current-clamp, and cell-attached patch-clamp recordings from specific circadian clock neurons in Drosophila. We perform quantitative comparisons based on the variability of functional biophysical parameters used in various electrophysiological methods, and advanced statistical comparisons based on the degree of stationariness and signal-to-noise ratio. RESULTS: Results indicate a dramatic reduction in artifactual variabilities of functional parameters from enhanced stability. We also identify significant exclusions of a statistically estimated noise component in a time series of membrane voltage signals, improving signal-to-noise ratio. COMPARISON WITH EXISTING METHODS: Compared to standard glass electrodes, using membrane-coated glass electrodes achieves improved recording quality in intracellular electrophysiology. CONCLUSIONS: Electrophysiological recordings from Drosophila central neurons can be technically challenging, however, membrane-coated electrodes will possibly be beneficial for reliable data acquisition and improving the technical feasibility of axonal intracellular activities measurements and single-channel recordings. The improved electrical stability of the recordings should also contribute to increased mechanical stability, thus facilitating long-term stable measurements of neural activity. Therefore, it is possible that membrane-coated electrodes will be useful for any model system.


Asunto(s)
Drosophila , Neuronas , Animales , Electrodos , Potenciales de la Membrana/fisiología , Neuronas/fisiología , Electrofisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...